Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 104
Filtrar
1.
Heart Rhythm O2 ; 5(3): 150-157, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38560374

RESUMO

Background: The outcomes of left bundle branch pacing (LBBP) and left ventricular septal pacing (LVSP) in patients with heart failure remain to be learned. Objective: The objective of this study was to assess the echocardiographic and clinical outcomes of LBBP, LVSP, and deep septal pacing (DSP). Methods: This retrospective study included patients who met the criteria for cardiac resynchronization therapy (CRT) and underwent attempted LBBP in 5 Mayo centers. Clinical, electrocardiographic, and echocardiographic data were collected at baseline and follow-up. Results: A total of 91 consecutive patients were included in the study. A total of 52 patients had LBBP, 25 had LVSP, and 14 had DSP. The median follow-up duration was 307 (interquartile range 208, 508) days. There was significant left ventricular ejection fraction (LVEF) improvement in the LBBP and LVSP groups (from 35.9 ± 8.5% to 46.9 ± 10.0%, P < .001 in the LBBP group; from 33.1 ± 7.5% to 41.8 ± 10.8%, P < .001 in the LVSP group) but not in the DSP group. A unipolar paced right bundle branch block morphology during the procedure in lead V1 was associated with higher odds of CRT response. There was no significant difference in heart failure hospitalization and all-cause deaths between the LBBP and LVSP groups. The rate of heart failure hospitalization and all-cause deaths were increased in the DSP group compared with the LBBP group (hazard ratio 5.10, 95% confidence interval 1.14-22.78, P = .033; and hazard ratio 7.83, 95% confidence interval 1.38-44.32, P = .020, respectively). Conclusion: In patients undergoing CRT, LVSP had comparable CRT outcomes compared with LBBP.

2.
Circ Arrhythm Electrophysiol ; 17(2): e012377, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38288627

RESUMO

BACKGROUND: The incidence and prognosis of right bundle branch block (RBBB) following transcatheter aortic valve replacement (TAVR) are unknown. Hence, we sought to characterize the incidence of post-TAVR RBBB and determine associated risks of permanent pacemaker (PPM) implantation and mortality. METHODS: All patients 18 years and above without preexisting RBBB or PPM who underwent TAVR at US Mayo Clinic sites and Mayo Clinic Health Systems from June 2010 to May 2021 were evaluated. Post-TAVR RBBB was defined as new-onset RBBB in the postimplantation period. The risks of PPM implantation (within 90 days) and mortality following TAVR were compared for patients with and without post-TAVR RBBB using Kaplan-Meier analysis and Cox proportional hazards modeling. The risks of PPM implantation (within 90 days) and mortality following TAVR were compared for patients with and without post-TAVR RBBB using Kaplan-Meier analysis and Cox proportional hazards modeling. RESULTS: Of 1992 patients, 15 (0.75%) experienced new RBBB post-TAVR. There was a higher degree of valve oversizing among patients with new RBBB post-TAVR versus those without (17.9% versus 10.0%; P=0.034). Ten patients (66.7%) with post-TAVR RBBB experienced high-grade atrioventricular block and underwent PPM implantation (median 1 day; Q1, 0.2 and Q3, 4), compared with 268/1977 (13.6%) without RBBB. Following propensity score adjustment for covariates (age, sex, balloon-expandable valve, annulus diameter, and valve oversizing), post-TAVR RBBB was significantly associated with PPM implantation (hazard ratio, 8.36 [95% CI, 4.19-16.7]; P<0.001). No statistically significant increase in mortality was seen with post-TAVR RBBB (hazard ratio, 0.83 [95% CI, 0.33-2.11]; P=0.69), adjusting for age and sex. CONCLUSIONS: Although infrequent, post-TAVR RBBB was associated with elevated PPM implantation risk. The mechanisms for its development and its clinical prognosis require further study.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/etiologia , Estenose da Valva Aórtica/cirurgia , Incidência , Estimulação Cardíaca Artificial/efeitos adversos , Resultado do Tratamento , Fatores de Risco , Valva Aórtica/cirurgia
3.
J Interv Card Electrophysiol ; 67(2): 319-328, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37392273

RESUMO

BACKGROUND: Adults with congenital heart disease (ACHD) have increased risk of arrhythmias warranting implantation of cardiac implantable electronic devices (CIEDs), which may parallel the observed increase in survival of ACHD patients over the past few decades. We sought to characterize the trends and outcomes of CIED implantation in the inpatient ACHD population across US from 2005 to 2019. METHODS: A retrospective analysis of the Nationwide Inpatient Sample (NIS) identified 1,599,519 unique inpatient ACHD admissions (stratified as simple (85.1%), moderate (11.5%), and complex (3.4%)) using the International Classification of Diseases 9/10-CM codes. Hospitalizations for CIED implantation (pacemaker, ICD, CRT-p/CRT-d) were identified and the trends analyzed using regression analysis (2-tailed p < 0.05 was considered significant). RESULTS: A significant decrease in the hospitalizations for CIED implantation across the study period [3.3 (2.9-3.8)% in 2005 vs 2.4 (2.1-2.6)% in 2019, p < 0.001] was observed across all types of devices and CHD severities. Pacemaker implantation increased with each age decade, whereas ICD implantation rates decreased over 70 years of age. Complex ACHD patients receiving CIED were younger with a lower prevalence of age-related comorbidities, however, had a greater prevalence of atrial/ventricular tachyarrhythmias and complete heart block. The observed inpatient mortality rate was 1.2%. CONCLUSIONS: In a nationwide analysis, we report a significant decline in CIED implantation between 2005 and 2019 in ACHD patients. This may either be due to a greater proportion of hospitalizations resulting from other complications of ACHD or reflect a declining need for CIED due to advances in medical/surgical therapies. Future prospective studies are needed to elucidate this trend further.


Assuntos
Desfibriladores Implantáveis , Cardiopatias Congênitas , Marca-Passo Artificial , Adulto , Humanos , Idoso , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Desfibriladores Implantáveis/efeitos adversos , Cardiopatias Congênitas/epidemiologia , Cardiopatias Congênitas/terapia , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia
4.
Open Forum Infect Dis ; 10(7): ofad318, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37426953

RESUMO

Background: In contrast to bloodstream infection due to a variety of bacteria in patients with cardiovascular implantable electronic devices (CIED), there are limited data regarding candidemia and risk of CIED infection. Methods: All patients with candidemia and a CIED at Mayo Clinic Rochester between 2012 and 2019 were reviewed. Cardiovascular implantable electronic device infection was defined by (1) clinical signs of pocket site infection or (2) echocardiographic evidence of lead vegetations. Results: A total of 23 patients with candidemia had underlying CIED; 9 (39.1%) cases were community onset. None of the patients had pocket site infection. The duration between CIED placement and candidemia was prolonged (median 3.5 years; interquartile range, 2.0-6.5). Only 7 (30.4%) patients underwent transesophageal echocardiography and 2 of 7 (28.6%) had lead masses. Only the 2 patients with lead masses underwent CIED extraction, but device cultures were negative for Candida species. Two (33.3%) of 6 other patients who were managed as candidemia without device infection subsequently developed relapsing candidemia. Cardiovascular implantable electronic device removal was done in both patients and device cultures grew Candida species. Although 17.4% of patients were ultimately confirmed to have CIED infection, CIED infection status was undefined in 52.2%. Overall, 17 (73.9%) patients died within 90 days of diagnosis of candidemia. Conclusions: Although current international guidelines recommend CIED removal in patients with candidemia, the optimal management strategy remains undefined. This is problematic because candidemia alone is associated with increased morbidity and mortality as seen in this cohort. Moreover, inappropriate device removal or retention can both result in increased patient morbidity and mortality.

5.
Circ Arrhythm Electrophysiol ; 16(8): 437-446, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37485717

RESUMO

BACKGROUND: The outcomes of catheter ablation for atrial fibrillation in adults with congenital heart disease are not well described. METHODS: In a retrospective study of adult patients with congenital heart disease who underwent catheter ablation for atrial fibrillation between 2000 and 2020 at Mayo Clinic, procedural characteristics and outcomes were collected. The primary outcomes were atrial arrhythmia (AA) recurrence following a 3-month blanking period and repeat ablation. An arrhythmia clinical severity score was assessed pre- and post-ablation based on the duration of arrhythmia episodes, symptoms, cardioversion frequency, and antiarrhythmic drug use. RESULTS: One hundred forty-five patients (age, 57±12 years; 28% female; 63% paroxysmal atrial fibrillation) underwent 198 ablations with a median follow-up of 26 months (interquartile range, 14-69). One hundred ten, 26, and 9 patients had simple, moderate, and complex congenital heart disease, respectively. All patients underwent pulmonary vein isolation, and non-pulmonary vein targets were ablated in 79 (54%). AA recurrence at 12 months was 37% (95% CI, 29%-45%). On univariate analysis, increasing left atrial volume index was associated with higher odds of AA recurrence (odds ratio, 1.03 [1.00-1.06] per 1 mL/m2 increment; P=0.05). Noninducibility of atrial flutter was predictive of decreased odds of AA recurrence (odds ratio, 0.43 [0.21-0.90]; P=0.03). A second ablation was performed in 43 patients after a median of 20 (interquartile range, 8-37) months. Arrhythmia clinical severity scores improved following ablation, reflecting a decrease in symptoms, cardioversions, and antiarrhythmic drugs. CONCLUSIONS: Catheter ablation of atrial fibrillation is feasible and effective in patients with adult congenital heart disease and reduces symptoms. Recurrence of AA frequently requires repeat ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Cardiopatias Congênitas , Veias Pulmonares , Humanos , Adulto , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/cirurgia , Antiarrítmicos/uso terapêutico , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Recidiva
6.
Am Heart J ; 263: 141-150, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37271358

RESUMO

BACKGROUND: Adults with repaired tetralogy of Fallot (TOF) have right atrial (RA) remodeling and dysfunction, and RA function can be measured using speckle tracking echocardiography. There are limited data about the role of RA strain imaging for risk stratification in this population. We hypothesized that RA reservoir strain can identify TOF patients at risk of developing atrial arrhythmia. To test this hypothesis, we assessed the relationship between RA reservoir strain and atrial arrhythmias in adults with repaired TOF. METHOD: Retrospective cohort study of adults with repaired TOF, and no prior history of atrial arrhythmias. Atrial arrhythmia was defined as atrial fibrillation, atrial flutter/atrial tachycardia, and categorized as new-onset versus recurrent atrial arrhythmias. RESULTS: We identified 426 patients (age 33 ± 12 years; males 208 (49%)) that met the inclusion criteria. The mean RA reservoir strain, conduit strain, and booster strain were 34 ± 11%, 20 ± 9%, and 15 ± 12%, respectively. Of 426 patients, 73 (17%) developed new-onset atrial arrhythmias (atrial flutter/tachycardia n = 42; atrial fibrillation n = 31); annual incidence 1.9%. RA reservoir strain was associated with new-onset atrial arrhythmias (adjusted HR 0.95, 95% CI 0.93-0.97) after multivariable adjustment. Of 73 patients with new-onset atrial arrhythmia, 41 (56%) had recurrent atrial arrhythmia (atrial flutter/tachycardia n = 18; atrial fibrillation n = 23); annual incidence 11.2%. Similarly, RA reservoir strain was associated with recurrent atrial arrhythmias (adjusted HR 0.92, 95% CI 0.88-0.96) after multivariable adjustment. CONCLUSIONS: RA strain indices can identify patients at risk for atrial arrhythmias, and this can in turn, be used to guide the type/intensity of therapy in such patients.


Assuntos
Fibrilação Atrial , Flutter Atrial , Taquicardia Supraventricular , Tetralogia de Fallot , Masculino , Humanos , Adulto , Adulto Jovem , Pessoa de Meia-Idade , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/etiologia , Fibrilação Atrial/terapia , Flutter Atrial/epidemiologia , Flutter Atrial/etiologia , Flutter Atrial/terapia , Tetralogia de Fallot/complicações , Tetralogia de Fallot/cirurgia , Estudos Retrospectivos , Taquicardia
7.
Heart Rhythm ; 20(8): 1111-1118, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37075957

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) safety in patients with an epicardial cardiac implantable electronic device (CIED) is uncertain. OBJECTIVE: The purpose of this study was to assess the safety and adverse effects of MRI in patients who had surgically implanted epicardial CIED. METHODS: Patients with surgically implanted CIEDs who underwent MRI with an appropriate cardiology-radiology collaborative protocol between January 2008 and January 2021 were prospectively studied in 2 clinical centers. All patients underwent close cardiac monitoring through MRI procedures. Outcomes were compared between the epicardial CIED group and the matched non-MRI-conditional transvenous CIED group. RESULTS: Twenty-nine consecutive patients with epicardial CIED (41.4% male; mean age 43 years) underwent 52 MRIs in 57 anatomic regions. Sixteen patients had a pacemaker, 9 had a cardiac defibrillator or cardiac resynchronization therapy-defibrillator, and 4 had no device generator. No significant adverse events occurred in the epicardial or transvenous CIED groups. Battery life, pacing, sensing thresholds, lead impedance, and cardiac biomarkers were not significantly changed, except 1 patient had a transient decrease in atrial lead sensing function. CONCLUSION: MRI of CIEDs with epicardially implanted leads does not represent a greater risk than transvenous CIEDs when performed with a multidisciplinary collaborative protocol centered on patient safety.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Masculino , Adulto , Feminino , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Coração , Segurança do Paciente
8.
Heart Rhythm O2 ; 4(3): 207-214, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36993918

RESUMO

Background: Cardiovascular implantable electronic device (CIED) infection carries significant morbidity and mortality with bacteremia being a possible marker of device infection. A clinical profile of non-Staphylococcus aureus gram-positive cocci (non-SA GPC) bacteremia in patients with CIED has been limited. Objective: To examine characteristics of patients with CIED who developed non-SA GPC bacteremia and risk of CIED infection. Methods: We reviewed all patients with CIED who developed non-SA GPC bacteremia at the Mayo Clinic between 2012 and 2019. The 2019 European Heart Rhythm Association Consensus Document was used to define CIED infection. Results: A total of 160 patients with CIED developed non-SA GPC bacteremia. CIED infection was present in 90 (56.3%) patients, in whom 60 (37.5%) were classified as definite and 30 (18.8%) as possible. This included 41 (45.6%) cases of coagulase-negative Staphylococcus (CoNS), 30 (33.3%) cases of Enterococcus, 13 (14.4%) cases of viridans group streptococci (VGS), and 6 (6.7%) cases of other organisms. The adjusted odds of CIED infection in cases due to CoNS, Enterococcus, and VGS bacteremia were 19-, 14-, and 15-fold higher, respectively, as compared with other non-SA GPC. In patients with CIED infection, the reduction in risk of 1-year mortality associated with device removal was not statistically significant (hazard ratio 0.59; 95% confidence interval 0.26-1.33; P = .198). Conclusions: The prevalence of CIED infection in non-SA GPC bacteremia was higher than previously reported, particularly in cases due to CoNS, Enterococcus species, and VGS. However, a larger cohort is needed to demonstrate the benefit of CIED extraction in patients with infected CIED due to non-SA GPC.

9.
BMC Cardiovasc Disord ; 23(1): 83, 2023 02 11.
Artigo em Inglês | MEDLINE | ID: mdl-36774486

RESUMO

BACKGROUND: Atrial fibrillation (AF) is relatively less frequent in younger patients (age < 50). Recently, studies have suggested that early restoration of sinus rhythm may lead to improved outcomes compared with rate control, however the efficacy of catheter ablation for AF in young is scarce. METHODS: We included all hospitalized patients between 18 and 50 years with a diagnosis of AF from the Nationwide Readmission Database 2016-2017 from the Healthcare Cost and Utilization Project. Demographic and comorbidity data were collected and analyzed. Outcomes assessed included one-year AF readmission rates, all-cause readmission, ischemic stroke, and all-cause mortality. Subgroup analyses were performed for all demographic and comorbidity variables. RESULTS: Overall, 52,598 patients (medium age 44, interquartile range 38-48, female 25.7%) were included in the study, including 2,146 (4.0%) who underwent catheter ablation for AF. Patients who underwent catheter ablation had a significantly lower rate of readmission for AF or any cause at one year (adjusted hazard ratios (HR) of 0.52 [95% confidence interval (CI): 0.43-0.63] and HR of 0.81 [95% CI: 0.72-0.89], respectively). There was no difference in 1-year readmission for stroke or all-cause mortality between the two groups. Subgroup analyses showed a consistent reduction in the risk of AF readmission among major demographic and comorbidity subgroups. CONCLUSION: Catheter ablation in young patients with AF was associated with a reduction in 1-year AF related and all-cause readmissions. These data merit further prospective investigation for validation, through dedicated registries and multicenter collaborations to include young AF from diverse population.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Acidente Vascular Cerebral , Humanos , Feminino , Adulto , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/epidemiologia , Fatores de Risco , Comorbidade , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento , Ablação por Cateter/efeitos adversos
10.
JACC Clin Electrophysiol ; 9(3): 385-393, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36752449

RESUMO

BACKGROUND: Dyssynchrony-associated left ventricular systolic dysfunction is a major contributor to heart failure in congenital heart disease (CHD). Although conventional cardiac resynchronization therapy (CRT) has shown benefit, the comparative efficacy of cardiac conduction system pacing (CSP) is unknown. OBJECTIVES: The purpose of this study was compare the clinical outcomes of CSP vs conventional CRT in CHD with biventricular, systemic left ventricular anatomy. METHODS: Retrospective CSP data from 7 centers were compared with propensity score-matched conventional CRT control subjects. Outcomes were lead performance, change in left ventricular ejection fraction (LVEF), and QRS duration at 12 months. RESULTS: A total of 65 CSP cases were identified (mean age 37 ± 21 years, 46% men). The most common CHDs were tetralogy of Fallot (n = 12 [19%]) and ventricular septal defect (n = 12 [19%]). CSP was achieved after a mean of 2.5 ± 1.6 attempts per procedure (38 patients with left bundle branch pacing, 17 with HBP, 10 with left ventricular septal myocardial). Left bundle branch area pacing [LBBAP] vs HBP was associated with a smaller increase in pacing threshold (Δ pacing threshold 0.2 V vs 0.8 V; P = 0.05) and similar sensing parameters at follow-up. For 25 CSP cases and control subjects with baseline left ventricular systolic dysfunction, improvement in LVEF was non-inferior (Δ LVEF 9.0% vs 6.0%; P = 0.30; 95% confidence limits: -2.9% to 10.0%) and narrowing of QRS duration was more pronounced for CSP (Δ QRS duration 35 ms vs 14 ms; P = 0.04). Complications were similar (3 [12%] CSP, 4 [16%] conventional CRT; P = 1.00). CONCLUSIONS: CSP can be reliably achieved in biventricular, systemic left ventricular CHD patients with similar improvement in LVEF and greater QRS narrowing for CSP vs conventional CRT at 1 year. Among CSP patients, pacing electrical parameters were superior for LBBAP vs HBP.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiopatias Congênitas , Disfunção Ventricular Esquerda , Masculino , Humanos , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Feminino , Terapia de Ressincronização Cardíaca/efeitos adversos , Bloqueio de Ramo , Fascículo Atrioventricular , Volume Sistólico , Estudos Retrospectivos , Eletrocardiografia , Função Ventricular Esquerda , Resultado do Tratamento , Doença do Sistema de Condução Cardíaco , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/terapia , Disfunção Ventricular Esquerda/terapia
11.
Heart ; 109(6): 442-448, 2023 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-36368881

RESUMO

OBJECTIVE: Supraventricular arrhythmias are common in adults with Ebstein anomaly (EA). However, there are limited data about prognostic implications of atrial fibrillation (AF) in this population. Accordingly, our aim was to assess the clinical profile and burden of AF in adults with EA, and the relationship between AF and outcomes. METHODS AND RESULTS: Six hundred eighty-two consecutive adults with a median age of 36 (24-49) years from Mayo Clinic, Minnesota, USA, between 2003 and 2020 were included. Sustained episodes of AF, clinical, echocardiographic, rhythm and surgical data were collected. Prevalence of AF at baseline was 18% (126 patients); the first episode occurred at a mean age of 43±17 years. Patients with AF were older, were more likely men, and had hypertension, renal dysfunction, cardiac devices, and more advanced right-sided and left-sided remodelling. During a median follow-up of 156 (81-240) months, 62 patients (11%) developed incident AF. At the last encounter, prevalence of AF was 28% (188 patients); of those, 63 (34%) had recurrent AF. Hospitalisation for heart failure (HF) occurred in 51 patients (7%). AF (HR 2.32, 95% CI 1.18 to 4.47; p=0.01) was independently associated with hospitalisation for HF. All-cause death occurred in 53 patients (8%); it was more frequent in those with AF in the univariable analysis, although it did not remain significant in the multivariable analysis. CONCLUSIONS: AF in EA develops at relatively young ages with one-third of the cohort exhibiting a recurrent pattern. Patients with AF had a higher prevalence of comorbidities and worse right-sided and left-sided cardiac remodelling. AF was independently associated with HF hospitalisation.


Assuntos
Fibrilação Atrial , Anomalia de Ebstein , Insuficiência Cardíaca , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Fibrilação Atrial/complicações , Prognóstico , Estudos Retrospectivos , Coração , Insuficiência Cardíaca/complicações
12.
Am J Cardiol ; 186: 5-10, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36334435

RESUMO

This study aimed to elucidate a potential dose-dependent relation between coffee intake and atrial fibrillation (AF) incidence in a multi-ethnic setting. Previous studies were comprised mainly of White populations, and an exploration of dose dependency is limited. To address these gaps, we analyzed the Multi-Ethnic Study of Atherosclerosis data, a prospective cohort study. In the primary analysis, we crudely divided patients into 3 groups: nonconsumers, 1 to 3 cups/month, and ≥1 cup/week. For the secondary analysis, we stratified the cohort into 9 groups of gradual increments for coffee consumption. A multivariable cox proportional hazards regression model was adjusted for 6 potential confounders: age, gender, smoking, hypertension, diabetes mellitus, and alcohol. Subjects who drank ≥1 cup of coffee/week had a higher incidence of AF (adjusted hazard ratio 1.40, p = 0.015) than nonconsumers. Furthermore, in the secondary analysis, there was an overall trend, albeit not consistent, of increasing adjusted hazard ratio with progressively increasing doses of coffee in the following groups: 1 to 3 cups/month, 2 to 4 cups/week, 2 to 3 cups/day and ≥6 cups/day. Notably, AF incidence was highest (9.8%) for the group consuming the most coffee, that is, ≥6 cups/day (p = 0.02). Stratification by race/ethnicity suggested the results may be driven by White and Hispanic rather than Black or Chinese-American subgroups. In conclusion, the findings suggest an association between coffee consumption and incident AF in contrast to most previous studies.


Assuntos
Aterosclerose , Fibrilação Atrial , Humanos , Etnicidade , Fibrilação Atrial/epidemiologia , Estudos Prospectivos , Fatores de Risco , Incidência
13.
J Cardiovasc Electrophysiol ; 34(1): 229-230, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35946395

RESUMO

A 70-year-old woman with longstanding persistent atrial fibrillation underwent Micra leadless pacemaker implantation and atrioventricular nodal ablation. No postprocedural complications were noted. She subsequently underwent surgical mitral valve replacement 4 years later. During the surgery, Micra tine perforation of the right ventricular free wall was seen. No device revision was performed due to her asymptomatic status and stable pacemaker position/function. Pericardial effusion is a known complication of Micra implantation. The incidence of tine perforation is unknown as many patients may be asymptomatic. The clinical consequences regarding adverse events, device functionality, and explantation/extraction risk profile remain to be determined.


Assuntos
Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Marca-Passo Artificial , Humanos , Feminino , Idoso , Resultado do Tratamento , Marca-Passo Artificial/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Nó Atrioventricular
14.
J Am Heart Assoc ; 11(22): e025121, 2022 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-36346046

RESUMO

Background The objective of this international multicenter study was to investigate both early and late outcomes of cardiac resynchronization therapy (CRT) in patients with a systemic right ventricle (SRV) and to identify predictors for congestive heart failure readmissions and mortality. Methods and Results This retrospective international multicenter study included 13 centers. The study population comprised 80 adult patients with SRV (48.9% women) with a mean age of 45±14 (range, 18-77) years at initiation of CRT. Median follow-up time was 4.1 (25th-75th percentile, 1.3-8.3) years. Underlying congenital heart disease consisted of congenitally corrected transposition of the great arteries and dextro-transposition of the great arteries in 63 (78.8%) and 17 (21.3%) patients, respectively. CRT resulted in significant improvement in functional class (before CRT: III, 25th-75th percentile, II-III; after CRT: II, 25th-75th percentile, II-III; P=0.005) and QRS duration (before CRT: 176±27; after CRT: 150±24 milliseconds; P=0.003) in patients with pre-CRT ventricular pacing who underwent an upgrade to a CRT device (n=49). These improvements persisted during long-term follow-up with a marginal but significant increase in SRV function (before CRT; 30%, 25th-75th percentile, 25-35; after CRT: 31%, 25th-75th percentile, 21-38; P=0.049). In contrast, no beneficial change in the above-mentioned variables was observed in patients who underwent de novo CRT (n=31). A quarter of all patients were readmitted for heart failure during follow-up, and mortality at latest follow-up was 21.3%. Conclusions This international experience with CRT in patients with an SRV demonstrated that CRT in selected patients with SRV dysfunction and pacing-induced dyssynchrony yielded consistent improvement in QRS duration and New York Heart Association functional status, with a marginal increase in SRV function.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Transposição dos Grandes Vasos , Humanos , Adulto , Feminino , Pessoa de Meia-Idade , Masculino , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Ventrículos do Coração , Estudos Retrospectivos , Resultado do Tratamento , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia
15.
Circ Arrhythm Electrophysiol ; 15(9): e011088, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36074649

RESUMO

BACKGROUND: Mitral annular disjunction (MAD) has recently been recognized as an arrhythmogenic entity. Data on the electrophysiological substrate as well as the outcomes of catheter ablation of ventricular arrhythmias in patients with MAD is limited. METHODS: Forty patients with MAD (mean age 47±15 years; 70% female) underwent catheter ablation for ventricular arrhythmias. Detailed clinical, electrocardiographic, cardiac imaging, and procedural data were collected. Clinical outcomes were compared between patients who had substrate modification in the MAD area and those who did not. RESULTS: Twenty-three (57.5%) patients had ablation for premature ventricular contractions, 10 (25%) patients for sustained ventricular tachycardia, and 7 (17.5%) patients for premature ventricular contraction-triggered ventricular fibrillation. Mean end-systolic MAD length was 10.58±3.49 mm on transthoracic echocardiography. Seventeen (42.5%) patients had preprocedural cardiac magnetic resonance imaging, and 5 (29%) patients had late gadolinium enhancement. Among the 18 (45%) patients who had abnormal local electrograms (low voltage, long-duration, fractionated, isolated mid-diastolic potentials) during electroanatomical mapping, 10 (25%) patients had abnormal electrograms in the anterolateral mitral annulus and/or MAD area. Substrate modification was performed in 10 (25%) patients. Catheter ablation was acutely successful in 36 (90%) patients (elimination of premature ventricular contraction or noninducibility of ventricular tachycardia). After a median follow-up duration of 54.08 (interquartile range, 10.67-89.79) months, premature ventricular contraction burden decreased from a median of 9.75% (interquartile range, 3.25-14) before the ablation to a median of 4% (interquartile range, 1-7.75) after the ablation (P=0.03 [95% CI, 0.055-6.5]). Eight (20.5%) patients had repeat ablation for ventricular arrhythmias. Substrate modification of the MAD was associated with a trend toward lower rates of repeat ablation (0% versus 26.7%; P=0.16). CONCLUSIONS: Patients with MAD have a complex arrhythmogenic substrate, and catheter ablation is effective in reducing recurrence of ventricular arrhythmias. Substrate mapping and ablation may be considered in these patients.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Adulto , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Meios de Contraste , Feminino , Gadolínio , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia
16.
Open Forum Infect Dis ; 9(9): ofac444, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36092830

RESUMO

Background: Gram-negative bacteremia (GNB) as a manifestation of cardiovascular implantable electronic device (CIED) infection is uncommon. Moreover, echocardiography may be nonspecific in its ability to differentiate whether CIED lead masses are infected. We aimed to determine the rate of CIED infection in the setting of GNB. Methods: All patients with CIED who were hospitalized with GNB during 2012-2019 at Mayo Clinic were investigated. The definition of CIED infection was based on criteria recommended by the 2019 European Heart Rhythm Association document. Results: A total of 126 patients with CIED developed GNB. None of them had signs of pocket infection. Twenty (15.9%) patients underwent transesophageal echocardiography. Overall, 4 (3%) patients had definite CIED infection. None of them underwent CIED extraction; 3 died within 12 weeks and 1 received long-term antibiotic suppression. Ten (8%) patients had possible CIED infection; despite no CIED extraction, no patient had relapsing GNB. We observed a higher rate of CIED infection in patients with Serratia marcescens bacteremia as compared to that in patients with other GNB. Conclusions: The rate of CIED infection following GNB was relatively low. However, accurate classification of CIED infection among patients presenting with GNB remains challenging, in part, due to a case definition of CIED infection that is characterized by a low pretest probability in the setting of GNB. Prospective, multicenter studies are needed to determine accurate identification of CIED infection among GNB, so that only patients with true infection undergo device removal.

17.
Mayo Clin Proc ; 97(8): 1493-1500, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35933135

RESUMO

OBJECTIVE: To characterize the physical activity (PA) level in patients with a cardiac implantable electronic device (CIED) during the coronavirus disease 2019 (COVID-19) pandemic and compare PA level during the pandemic in 2020 with the year 2019. METHODS: We performed a retrospective analysis of PA activity in individuals implanted with a CIED enrolled in the BIOTRONIK CERTITUDE Registry. Mean daily and weekly PA from January to August 2020 was compared with 2019. RESULTS: A total of 21,660 individuals met eligibility criteria, with mean age of 72.6±11.6 years, and 12,411 (57.3)% were males. A significant decline in daily PA was noted following the pandemic declaration in 2020, with a maximum mean reduction of -24.5±36.3 minutes (P<.0001) observed in April 2020 compared with 2019. PA in 2020 increased from April to May (120.6±67.4 to 129.2±70.9 min/d). PA was lower for all months in 2020 compared with 2019. The decrease in PA was observed in all prespecified groups based on age, sex, type of device, and region of the country. CONCLUSION: After the declaration of the coronavirus disease 2019 pandemic, a significant decline in daily PA was observed in individuals with a CIED. Future investigation to establish the impact of this reduction on short and long-term cardiovascular outcomes is required.


Assuntos
COVID-19 , Desfibriladores Implantáveis , Idoso , Idoso de 80 Anos ou mais , COVID-19/epidemiologia , Eletrônica , Exercício Físico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pandemias , Estudos Retrospectivos
18.
Circ Arrhythm Electrophysiol ; 15(7): e010744, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35763435

RESUMO

BACKGROUND: Optimal management of cardiac implantable electronic devices (CIEDs) in patients with Ebstein anomaly during tricuspid valve (TV) surgery is unknown. Thus, we aimed to characterize CIED management/outcomes in patients with Ebstein anomaly undergoing TV surgery. METHODS: Patients at the Mayo Clinic from 1987 to 2020 with Ebstein anomaly and CIED procedure were reviewed for procedural details, complications, echocardiogram, and lead parameters. Five-year cumulative incidence of CIED complications were estimated using the Kaplan-Meier method. RESULTS: Ninety-three patients were included; 51 were female, and mean age was 40.7±17.5 years. A new CIED was implanted in 45 patients at the time of TV surgery with the majority receiving an epicardial (n=37) CIED. Among 34 patients who had preexisting CIED (11 epicardial, 23 transvenous) at time of TV surgery, 20 had a transvenous right ventricular lead managed by externalizing the lead to the TV (n=15) or extracting the transvenous lead with epicardial lead implantation (n=5). Fourteen patients underwent CIED implantation (4 epicardial, 10 transvenous) without concurrent surgery. Placement of lead across the TV was avoided in 85% of patients. The 5-year cumulative incidence of CIED complications was 24% with no significant difference between epicardial and transvenous CIEDs (26% versus 23%, P=0.96). Performance of lead parameters was similar in epicardial and transvenous leads during median (interquartile range) follow-up of 44.5 (61.1) months. CONCLUSIONS: In patients with Ebstein anomaly undergoing TV surgery, the use of epicardial leads and externalization of transvenous leads to the TV can avoid lead placement across the valve leaflets. Lead performance and CIED complications was similar between epicardial and transvenous CIEDs.


Assuntos
Desfibriladores Implantáveis , Anomalia de Ebstein , Marca-Passo Artificial , Adulto , Desfibriladores Implantáveis/efeitos adversos , Anomalia de Ebstein/etiologia , Anomalia de Ebstein/cirurgia , Eletrônica , Feminino , Coração , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
19.
Circ Arrhythm Electrophysiol ; 15(7): e010546, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35763440

RESUMO

BACKGROUND: Patients with D-transposition of the great arteries and atrial switch have a high incidence of atrial arrhythmias. We sought to analyze the arrhythmia substrate, ablation strategies, and outcomes for catheter ablation in this population. METHODS: An in-depth analysis of all clinical and procedural data in patients with D-transposition of the great arteries, atrial baffles, and atrial arrhythmia ablation was performed. RESULTS: A cohort of 32 patients (72% male, mean age 38±7 years) underwent ablation for non-AV nodal reentrant tachycardia atrial arrhythmias, and 4 patients underwent AV nodal reentrant tachycardia ablation. Cavotricuspid isthmus flutter (CTI-flutter) was the most common arrhythmia, encountered in 75% of patients, followed by scar-related intraatrial reentrant tachycardia (non-CTI intraatrial reentrant tachycardia, 53%) and focal atrial tachycardia (focal atrial tachycardia, 6%). Among the 32 patients, 26 underwent 31 procedures at our institution. For patients with prior outside intervention, the index ablation at our institution revealed CTI-dependent flutter in 3/5 cases. However, redo ablation after an index ablation with demonstrated bidirectional CTI block revealed different/new arrhythmia substrates (80% non-CTI intraatrial reentrant tachycardia, 40% focal atrial tachycardia). Achieving bidirectional block across the CTI often required ablating on both sides of the baffle (retroaortic access, 81%; using a baffle leak, 11.5%; or transbaffle puncture, 7.7%). Combined approaches were necessary in 19% to reach the critical tissue. Acute procedural success was 81%, and recurrence was documented in 58% of patients. Despite recurrence, clinical arrhythmia burden was significantly reduced post-ablation (P<0.001), with rare episodes, amenable to antiarrhythmic therapy. Redo ablation was required in 5 (19%) patients and uncovered new arrhythmia substrates. AV nodal reentrant tachycardia ablation also required transbaffle approaches in 3/4 patients. CONCLUSIONS: CTI-dependent flutter was the most common arrhythmia in patients with Dextro-Transposition of the Great Arteries and atrial switch. Transbaffle approaches were often necessary, and, provided that bidirectional CTI block was achieved at the index ablation, late recurrence was due to different arrhythmia mechanisms. Despite recurrence, ablation was associated with significant clinical improvement.


Assuntos
Flutter Atrial , Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Taquicardia Atrial Ectópica , Transposição dos Grandes Vasos , Adulto , Artérias/cirurgia , Flutter Atrial/diagnóstico , Flutter Atrial/etiologia , Flutter Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Atrial Ectópica/cirurgia , Transposição dos Grandes Vasos/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA